Well Casing

Our well casing is produced from Type 1, Grade 1 virgin compound which exceeds the materials requirements for ASTM Standard F-480. This product is specifically manufactured for use in water well construction.
IC-2 rated products are tested to withstand higher / more stringent impact standards.

Well Casing – Schedule 40 PVC
Standard Compliances:

  • ASTM D-1785, standard for pressure pipe (NSF®-pw-G)
  • ASTM D-2665, standard for DWV (NSF®-dwv)
  • ASTM F-480, standard for well casing (NSF®-wc)

Material complies with ANSI / NSF® Standard 14.
2″ – 10″ are laying length
4″ – 8″ are IC-2 Rated
5″ is dual rated Sch 40 / SDR 21

SCH 40 Well Casing. Belled End 20ft.

Resistance to Hydraulic Collapse
Nominal Size Item Number Outside Diameter Min. Wall Thickness Max Inside Diameter (Value) Min Inside Diameter (Value) Bell Depth (inch) Outside Bell Diameter Socket Entrance Diameter Wt/100' Ft/Pallet PSI Depth (FT)
2" 152071 2.375 0.154 2.073 2.021 3 1/2 2.712 2.386 70 2,800 291 672
3" 152079 3.500 0.216 3.076 3.008 5 1/4 3.972 3.514 144 1,500 250 577
4" 152081 4.500 0.237 4.035 3.961 6 5.019 4.517 205 580 152 351
5" 152108 5.563 0.265 5.043 4.975 7 6.146 5.584 295 460 111 256
6" 152118 6.625 0.280 6.076 5.986 7 7.242 6.648 364 520 77 178
8" 152127 8.625 0.322 7.996 7.888 7 1/4 9.332 8.649 546 280 52 120
10" 522039 10.750 0.365 10.035 9.917 8 11.570 10.796 753 220 39 90
12" 522041 12.750 0.406 11.953 11.825 9 1/2 13.639 12.778 1000 80 32 74

Well Casing – SDR 17 PVC
Standard Compliances:

  • ASTM F-480, standard for well casing (NSF®-wc)

Material complies with ANSI / NSF® Standard 14
All sizes are laying length and IC-2 Rated

SDR 17 Well Casing. Belled End 20ft.

Resistance to Hydraulic Collapse
Nominal Size Item Number Outside Diameter Min. Wall Thickness Max Inside Diameter (Value) Min Inside Diameter (Value) Bell Depth (inch) Outside Bell Diameter Socket Entrance Diameter Wt/100' Ft/Pallet PSI Depth (FT)
5" 152107 5.563 0.327 4.919 4.821 7 6.277 5.584 360 460 215 497
6" 152117 6.625 0.390 5.856 5.740 7 1/4 7.475 6.648 496 520 215 497

Well Casing – SDR 21 PVC
Standard Compliances:

  • ASTM D-2241, standard for pressure pipe (NSF®-pw-G)
  • ASTM F-480, standard for well casing (NSF®-wc)

Material complies with ANSI / NSF® Standard 14.
All sizes are laying length
5″ and 6″ are IC-2 rated
5″ is dual rated Sch 40 / SDR 21

SDR 21 Well Casing. Belled End 20ft.

Resistance to Hydraulic Collapse
Nominal Size Item Number Outside Diameter Min. Wall Thickness Max Inside Diameter (Value) Min Inside Diameter (Value) Bell Depth (inch) Outside Bell Diameter Socket Entrance Diameter Wt/100' Ft/Pallet PSI Depth (FT)
2" 225010 2.375 0.113 2.155 2.103 3 1/2 2.626 2.386 53 2,800 111 256
3" 225013 3.500 0.167 3.174 3.118 5 1/4 3.868 3.514 114 1,500 111 256
4" 152082 4.500 0.214 4.081 4.011 6 4.971 4.517 189 580 111 256
5" 152108 5.563 0.265 5.043 4.975 7 6.146 5.584 295 460 111 256
6" 152118 6.625 0.316 6.004 5.906 7 1/4 7.318 6.648 412 520 111 256
8" 152128 8.625 0.410 7.820 7.692 7 1/4 9.517 8.649 688 280 111 256
10" 152133 10.750 0.511 9.743 9.591 8 11.859 10.796 1088 220 111 256

Well Casing – SDR 26 PVC
Standard Compliances:

  • ASTM D-2241, standard for pressure pipe (NSF®-pw-G)
  • ASTM F-480, standard for well casing (NSF®-wc)

Material complies with ANSI / NSF® Standard 14.
All sizes are laying length
5″ – 8″ are IC-2 rated

SDR 26 Well Casing. Belled End 20ft.

Resistance to Hydraulic Collapse
Nominal Size Item Number Outside Diameter Min. Wall Thickness Max Inside Diameter (Value) Min Inside Diameter (Value) Bell Depth (inch) Outside Bell Diameter Socket Entrance Diameter Wt/100' Ft/Pallet PSI Depth (FT)
4" 152084 4.500 0.173 4.163 4.105 6 4.884 4.517 156 580 58 134
5" 152109 5.563 0.214 5.145 5.071 7 6.038 5.584 240 460 58 134
6" 152119 6.625 0.255 6.126 6.042 7 1/4 7.189 6.648 336 520 58 134

Well Casing – Specialty Sizes
Standard Compliances:

  • ASTM F-480, standard for well casing (NSF®-wc)

Material complies with ANSI / NSF® Standard 14.
All sizes are laying length and IC-2 rated
4-1/2″ is dual rated Sch 40 / SDR 21

Well Casing Specials. Belled End 20ft.

Resistance to Hydraulic Collapse
Nominal Size Item Number Product Type Outside Diameter Min. Wall Thickness Max Inside Diameter (Value) Min Inside Diameter (Value) Bell Depth (inch) Outside Bell Diameter Socket Entrance Diameter Wt/100' Ft/Pallet PSI Depth (FT)
4-1/2" 152098 SDR 17 4.950 0.291 4.378 4.308 6 1/4 5.585 4.968 275 520 215 497
4-1/2" 152099 SDR 21 4.950 0.190 4.580 4.510 6 1/4 5.371 4.968 187 520 58 134
4-1/2" 152097 SCH 40 / SDR 21 4.950 0.248 4.464 4.414 6 1/4 5.494 4.968 240 520 130 300
6-1/8" I.D. 152125 SDR 21 6.900 0.329 6.253 6.180 7 1/4 7.619 6.922 445 400 111 256
6-1/4" I.D. 152126 SDR 27.6 6.900 0.250 6.411 6.324 7 1/2 7.452 6.922 345 400 48 111